About: Severe cases infected with the coronavirus disease 2019 (COVID-19), named by the World Health Organization (WHO) on Feb. 11, 2020, tend to present a hypercatabolic state because of severe systemic consumption, and are susceptible to stress ulcers and even life-threatening gastrointestinal bleeding. Endoscopic diagnosis and treatment constitute an irreplaceable part in the handling of severe COVID-19 cases. Endoscopes, as reusable precision instruments with complicated structures, require more techniques than other medical devices in cleaning, disinfection, sterilization, and other reprocessing procedures. From 2016 to 2019, health care-acquired infection caused by improper endoscope reprocessing has always been among the top 5 on the list of top 10 health technology hazards issued by the Emergency Care Research Institute. Considering the highly infective nature of COVID-19 and the potential aerosol contamination therefrom, it is of pivotal significance to ensure that endoscopes are strictly reprocessed between uses. In accordance with the national standard “Regulation for Cleaning and Disinfection Technique of Flexible Endoscope (WS507-2016),” we improved the workflow of endoscope reprocessing including the selection of chemicals in an effort to ensure quality control throughout the clinical management towards COVID-19 patients. Based on the experience we attained from the 12 severe COVID-19 cases in our hospital who underwent endoscopy 23 times in total, the article provides an improved version of endoscopic reprocessing guidelines for bedside endoscopic diagnosis and treatment on COVID-19 patients for reference. ELECTRONIC SUPPLEMENTARY MATERIALS: The online version of this article (10.1631/jzus.B2000109) contains supplementary materials, which are available to authorized users   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • Severe cases infected with the coronavirus disease 2019 (COVID-19), named by the World Health Organization (WHO) on Feb. 11, 2020, tend to present a hypercatabolic state because of severe systemic consumption, and are susceptible to stress ulcers and even life-threatening gastrointestinal bleeding. Endoscopic diagnosis and treatment constitute an irreplaceable part in the handling of severe COVID-19 cases. Endoscopes, as reusable precision instruments with complicated structures, require more techniques than other medical devices in cleaning, disinfection, sterilization, and other reprocessing procedures. From 2016 to 2019, health care-acquired infection caused by improper endoscope reprocessing has always been among the top 5 on the list of top 10 health technology hazards issued by the Emergency Care Research Institute. Considering the highly infective nature of COVID-19 and the potential aerosol contamination therefrom, it is of pivotal significance to ensure that endoscopes are strictly reprocessed between uses. In accordance with the national standard “Regulation for Cleaning and Disinfection Technique of Flexible Endoscope (WS507-2016),” we improved the workflow of endoscope reprocessing including the selection of chemicals in an effort to ensure quality control throughout the clinical management towards COVID-19 patients. Based on the experience we attained from the 12 severe COVID-19 cases in our hospital who underwent endoscopy 23 times in total, the article provides an improved version of endoscopic reprocessing guidelines for bedside endoscopic diagnosis and treatment on COVID-19 patients for reference. ELECTRONIC SUPPLEMENTARY MATERIALS: The online version of this article (10.1631/jzus.B2000109) contains supplementary materials, which are available to authorized users
Subject
  • Zoonoses
  • Endoscopy
  • Viral respiratory tract infections
  • COVID-19
  • 2007 singles
  • Occupational safety and health
  • Physical chemistry
  • Diagnostic gastroenterology
  • Contemporary R&B ballads
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software