About: To reduce noise pollution and consequently stress during robot-assisted laparoscopic radical prostatectomy (RALP) the aim of our study was to evaluate the silent operation theatre optimisation system (SOTOS) in its effectiveness. In the operating room (OR) the noise level is between 80 and 85 decibel (dB). Noise corresponds to a major stress factor for surgical teams and especially surgeons. The use of the da Vinci surgical system entails an additional aspect of noise in the OR. The SOTOS surgical team used wired or wireless headphone/microphone combinations to communicate. We measured sound pressure levels in two different locations in the OR and the heart rate of every surgical team member as an indicator of the stress level. We further captured subjective acceptance of SOTOS as well as perioperative data such as surgical time. We prospectively randomised 32 RALP patients into two study arms. Sixteen surgeries were performed using SOTOS and 16 without (control). Overall, the mean sound pressure level in the SOTOS group was 3.6 dB lower compared to the control (p < 0.001). The highest sound pressure level measured was 96 dB in the control group. Mean heart rates were 81.3 beats/min for surgeons and 90.8 beats/min for circulating nurses. SOTOS had no statistically significant effect on mean heart rates of the operating team. Subjective acceptance of SOTO was high. Our prospective evaluation of SOTOS in RALP could show a significant noise reduction in the OR and a high acceptance by the surgical stuff.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • To reduce noise pollution and consequently stress during robot-assisted laparoscopic radical prostatectomy (RALP) the aim of our study was to evaluate the silent operation theatre optimisation system (SOTOS) in its effectiveness. In the operating room (OR) the noise level is between 80 and 85 decibel (dB). Noise corresponds to a major stress factor for surgical teams and especially surgeons. The use of the da Vinci surgical system entails an additional aspect of noise in the OR. The SOTOS surgical team used wired or wireless headphone/microphone combinations to communicate. We measured sound pressure levels in two different locations in the OR and the heart rate of every surgical team member as an indicator of the stress level. We further captured subjective acceptance of SOTOS as well as perioperative data such as surgical time. We prospectively randomised 32 RALP patients into two study arms. Sixteen surgeries were performed using SOTOS and 16 without (control). Overall, the mean sound pressure level in the SOTOS group was 3.6 dB lower compared to the control (p < 0.001). The highest sound pressure level measured was 96 dB in the control group. Mean heart rates were 81.3 beats/min for surgeons and 90.8 beats/min for circulating nurses. SOTOS had no statistically significant effect on mean heart rates of the operating team. Subjective acceptance of SOTO was high. Our prospective evaluation of SOTOS in RALP could show a significant noise reduction in the OR and a high acceptance by the surgical stuff.
Subject
  • Surgery
  • Acoustics
  • Cardiovascular physiology
  • Sounds by type
  • Image noise reduction techniques
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software