About: Abstract In the face of an almost unprecedented threat of a global pandemic of influenza it is imperative that stockpiling of appropriate drugs and devices begin now. One vital device is an appropriate syringe for delivering vaccine. With the potential for millions to be infected and the vaccine supply severely stretched it is imperative that the syringe used to vaccinate waste as little vaccine as possible and thus allow for a maximum number of persons to be vaccinated. Our study tested seven leading candidate vaccine syringes for dosing accuracy, dose-capacity per vial, medication wastage and a battery of ergonomic features. One device, the Flu+™ syringe, proved superior to the others in all important categories, possibly due to its low dead-space volume and its dosing accuracy. The data suggest that switching to this device from any of the others tested would provide between 2 and 19% additional vaccine doses per vial if the current 10-dose vials are used. Extrapolations from this data suggest that many thousands to millions of additional persons could be vaccinated in mass campaigns. Use of a syringe of this type, and the vaccine savings that would accrue, would likely be important in reducing morbidity and mortality in the event of a pandemic of influenza.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • Abstract In the face of an almost unprecedented threat of a global pandemic of influenza it is imperative that stockpiling of appropriate drugs and devices begin now. One vital device is an appropriate syringe for delivering vaccine. With the potential for millions to be infected and the vaccine supply severely stretched it is imperative that the syringe used to vaccinate waste as little vaccine as possible and thus allow for a maximum number of persons to be vaccinated. Our study tested seven leading candidate vaccine syringes for dosing accuracy, dose-capacity per vial, medication wastage and a battery of ergonomic features. One device, the Flu+™ syringe, proved superior to the others in all important categories, possibly due to its low dead-space volume and its dosing accuracy. The data suggest that switching to this device from any of the others tested would provide between 2 and 19% additional vaccine doses per vial if the current 10-dose vials are used. Extrapolations from this data suggest that many thousands to millions of additional persons could be vaccinated in mass campaigns. Use of a syringe of this type, and the vaccine savings that would accrue, would likely be important in reducing morbidity and mortality in the event of a pandemic of influenza.
Subject
  • Virology
  • Vaccination
  • Vaccines
  • Actuarial science
  • Medical equipment
  • Drug delivery devices
  • Drug paraphernalia
  • Arab inventions
  • 18th-century inventions
  • Egyptian inventions
  • New Zealand inventions
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software