About: Early and rapid detection of dengue virus (DENV) infection during the acute phase of illness is crucial for proper patient management and prevention of the spread of the infection. In the present study, the standardization and validation of a one step, four tube reverse transcription loop-mediated isothermal amplification assay (RT-LAMP) for rapid detection and serotyping of the DENV targeting NS1 gene using the Genie® II flourometer was carried out. The performance of the RT-LAMP was compared to RT-PCR, CDC 1-4 Real time PCR and the NS1 antigen ELISA, IgM and IgG anti DENV antibodies. Acute DENV infection was confirmed in 250/300 patients suspected clinically of DENV infection. RT- LAMP and CDC 1-4 Real time PCR assay was positive in 148/250 patients, while 92/250 patients were positive for anti- Dengue IgM and IgG antibodies. The RT-LAMP assay and the CDC real-time RT-PCR assay showed high concordance (k = 1.0). The detection rate of acute DENV infection improved to 96% (240/250) when the results of RT-LAMP were combined with NS1 Ag, IgM and IgG ELISA. The RT-LAMP had a detection limit of 100 copies for DEN-1 and DEN-2, 10 copies for DEN-3 and DEN-4 compared to 1000 copies for DEN-1 and DEN-2, 100 copies for DEN-3 and DEN-4 by the conventional RT-PCR. The assay showed 100% specificity. The RT-LAMP assay developed in this study has potential use for early clinical diagnosis, serotyping and surveillance of DENV infection in endemic countries such as India.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • Early and rapid detection of dengue virus (DENV) infection during the acute phase of illness is crucial for proper patient management and prevention of the spread of the infection. In the present study, the standardization and validation of a one step, four tube reverse transcription loop-mediated isothermal amplification assay (RT-LAMP) for rapid detection and serotyping of the DENV targeting NS1 gene using the Genie® II flourometer was carried out. The performance of the RT-LAMP was compared to RT-PCR, CDC 1-4 Real time PCR and the NS1 antigen ELISA, IgM and IgG anti DENV antibodies. Acute DENV infection was confirmed in 250/300 patients suspected clinically of DENV infection. RT- LAMP and CDC 1-4 Real time PCR assay was positive in 148/250 patients, while 92/250 patients were positive for anti- Dengue IgM and IgG antibodies. The RT-LAMP assay and the CDC real-time RT-PCR assay showed high concordance (k = 1.0). The detection rate of acute DENV infection improved to 96% (240/250) when the results of RT-LAMP were combined with NS1 Ag, IgM and IgG ELISA. The RT-LAMP had a detection limit of 100 copies for DEN-1 and DEN-2, 10 copies for DEN-3 and DEN-4 compared to 1000 copies for DEN-1 and DEN-2, 100 copies for DEN-3 and DEN-4 by the conventional RT-PCR. The assay showed 100% specificity. The RT-LAMP assay developed in this study has potential use for early clinical diagnosis, serotyping and surveillance of DENV infection in endemic countries such as India.
Subject
  • Centers for Disease Control and Prevention
  • Dengue fever
  • Medical research institutes in the United States
  • Buildings and structures in Atlanta
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software