About: BACKGROUND: The application of appropriate personal protective equipment for respiratory protection to health care workers is a cornerstone for providing safe healthcare in emergency departments. We investigated the protective effect and usefulness of loose-fitting powered air-purifying respirators (PAPRs) during chest compression. METHODS: This was a single-center simulation study performed from May 2019 to July 2019 in a tertiary hospital. We measured the concentrations of ambient aerosol and particles inside the loose-fitting PAPR during chest compression, and this ratio was set as the simulated workplace protecting factor (SWPF). According to the National Institute for Occupational Safety and Health regulations, the assigned protection factor (APF) of loose-fitting PAPRs is 25. Thus, the loose-fitting PAPRs were assumed to have a protective effect when the SWPF were ≥ 250 (APF × 10). We measured the SWPF of PAPR in real time during chest compression and also investigated the problems encountered during its use. RESULTS: Ninety-one participants (median age 29 [interquartile range (IQR): 26–32] years; 74% female) completed the simulation. None of the participants failed with SWPF below 250 during three sessions of chest compression. The median (IQR) values of SWPF at three cycles were 17,063 (10,145-26,373), 15,683 (9477-32,394), and 16,960 (7695-27,279). There was no disconnection of equipment or mechanical failures during chest compression. In addition, most participants (83%) replied that they rarely or never experienced difficulty in verbal communication and felt that the loose-fitting PAPR was comfortable. CONCLUSIONS: The loose-fitting PAPRs provided sufficient respiratory protection without disturbances during chest compression.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • BACKGROUND: The application of appropriate personal protective equipment for respiratory protection to health care workers is a cornerstone for providing safe healthcare in emergency departments. We investigated the protective effect and usefulness of loose-fitting powered air-purifying respirators (PAPRs) during chest compression. METHODS: This was a single-center simulation study performed from May 2019 to July 2019 in a tertiary hospital. We measured the concentrations of ambient aerosol and particles inside the loose-fitting PAPR during chest compression, and this ratio was set as the simulated workplace protecting factor (SWPF). According to the National Institute for Occupational Safety and Health regulations, the assigned protection factor (APF) of loose-fitting PAPRs is 25. Thus, the loose-fitting PAPRs were assumed to have a protective effect when the SWPF were ≥ 250 (APF × 10). We measured the SWPF of PAPR in real time during chest compression and also investigated the problems encountered during its use. RESULTS: Ninety-one participants (median age 29 [interquartile range (IQR): 26–32] years; 74% female) completed the simulation. None of the participants failed with SWPF below 250 during three sessions of chest compression. The median (IQR) values of SWPF at three cycles were 17,063 (10,145-26,373), 15,683 (9477-32,394), and 16,960 (7695-27,279). There was no disconnection of equipment or mechanical failures during chest compression. In addition, most participants (83%) replied that they rarely or never experienced difficulty in verbal communication and felt that the loose-fitting PAPR was comfortable. CONCLUSIONS: The loose-fitting PAPRs provided sufficient respiratory protection without disturbances during chest compression.
subject
  • Demographics
  • Asphyxia
  • Respirators
  • Headgear
  • Emergency medical responders
  • Physical chemistry
  • Safety engineering
  • Safety clothing
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software