About: Abstract A multiplex real-time PCR assay for the detection of Mycoplasma pneumoniae (MP181), Chlamydia (Chlamydophila) pneumoniae (CP-Arg), Legionella spp. (Pan-Leg), and the human RNase P (RNase P) gene was developed for rapid testing of atypical bacterial respiratory pathogens in clinical specimens. This method uses 4 distinct hydrolysis probes to detect 3 leading causes of community-acquired pneumonia. The assay was evaluated for specificity and sensitivity by testing against 35 related organisms, a dilution series of each specific target and 197 clinical specimens. Specificity testing demonstrated no cross-reactivity. A comparison to previously validated singleplex real-time PCR assays for each agent was also performed. The analytical sensitivity for specific pathogen targets in both the singleplex and multiplex was identical (50 fg), while efficiencies ranged from 82% to 97% for the singleplex assays and from 90% to 100% for the multiplex assay. The clinical sensitivity of the multiplex assay was improved for the Pan-Leg and CP-Arg targets when compared to the singleplex. The MP181 assay displayed equivalent performance. This multiplex assay provides an overall improvement in the diagnostic capability for these agents by demonstrating a sensitive, high-throughput and rapid method. This procedure may allow for a practical and efficient means to test respiratory clinical specimens for atypical pneumonia agents in health care settings and facilitate an appropriate public health response to outbreaks.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • Abstract A multiplex real-time PCR assay for the detection of Mycoplasma pneumoniae (MP181), Chlamydia (Chlamydophila) pneumoniae (CP-Arg), Legionella spp. (Pan-Leg), and the human RNase P (RNase P) gene was developed for rapid testing of atypical bacterial respiratory pathogens in clinical specimens. This method uses 4 distinct hydrolysis probes to detect 3 leading causes of community-acquired pneumonia. The assay was evaluated for specificity and sensitivity by testing against 35 related organisms, a dilution series of each specific target and 197 clinical specimens. Specificity testing demonstrated no cross-reactivity. A comparison to previously validated singleplex real-time PCR assays for each agent was also performed. The analytical sensitivity for specific pathogen targets in both the singleplex and multiplex was identical (50 fg), while efficiencies ranged from 82% to 97% for the singleplex assays and from 90% to 100% for the multiplex assay. The clinical sensitivity of the multiplex assay was improved for the Pan-Leg and CP-Arg targets when compared to the singleplex. The MP181 assay displayed equivalent performance. This multiplex assay provides an overall improvement in the diagnostic capability for these agents by demonstrating a sensitive, high-throughput and rapid method. This procedure may allow for a practical and efficient means to test respiratory clinical specimens for atypical pneumonia agents in health care settings and facilitate an appropriate public health response to outbreaks.
Subject
  • Primary care
  • Bacteria described in 1963
  • Laboratory techniques
  • EC 3.1.26
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software