About: Mitigation of the ongoing COVID-19 pandemic requires reliable and accessible laboratory diagnostic services. We evaluated the performance of one LDT and two commercial tests, cobas(R) SARS-CoV-2 (Roche) and Amplidiag(R) COVID-19 (Mobidiag), for the detection of SARS-CoV-2 RNA in respiratory specimens. 183 specimens collected from suspected COVID-19 patients were studied with all three methods to compare their performance. In relation to the reference standard, which was established as the result obtained by two of the three studied methods, the positive percent agreement (PPA) was highest for cobas(R) test (100%), followed by Amplidiag(R) test and the LDT (98.9%). The negative percent agreement (NPA) was lowest for cobas(R) test (89.4%), followed by Amplidiag(R) test (98.8%) and the highest value was obtained for LDT (100%). The dilution series conducted for specimens, however, suggests significantly higher sensitivity for the cobas(R) assay in comparison with the other two assays and the low NPA value may be due to the same reason. In general, all tested assays performed adequately. Both the time from sample to result and hands-on time per sample were shortest for cobas(R) test. Clinical laboratories need to be prepared for uninterrupted high-throughput testing during the coming months in mitigation of the pandemic. To secure that, it is of critical importance for clinical laboratories to maintain several simultaneous platforms in their SARS-CoV-2 nucleic acid testing.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • Mitigation of the ongoing COVID-19 pandemic requires reliable and accessible laboratory diagnostic services. We evaluated the performance of one LDT and two commercial tests, cobas(R) SARS-CoV-2 (Roche) and Amplidiag(R) COVID-19 (Mobidiag), for the detection of SARS-CoV-2 RNA in respiratory specimens. 183 specimens collected from suspected COVID-19 patients were studied with all three methods to compare their performance. In relation to the reference standard, which was established as the result obtained by two of the three studied methods, the positive percent agreement (PPA) was highest for cobas(R) test (100%), followed by Amplidiag(R) test and the LDT (98.9%). The negative percent agreement (NPA) was lowest for cobas(R) test (89.4%), followed by Amplidiag(R) test (98.8%) and the highest value was obtained for LDT (100%). The dilution series conducted for specimens, however, suggests significantly higher sensitivity for the cobas(R) assay in comparison with the other two assays and the low NPA value may be due to the same reason. In general, all tested assays performed adequately. Both the time from sample to result and hands-on time per sample were shortest for cobas(R) test. Clinical laboratories need to be prepared for uninterrupted high-throughput testing during the coming months in mitigation of the pandemic. To secure that, it is of critical importance for clinical laboratories to maintain several simultaneous platforms in their SARS-CoV-2 nucleic acid testing.
Subject
  • Zoonoses
  • Laboratories
  • COVID-19
  • 2019 disasters in China
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software