About: Abstract Liquid impingers are utilized to collect bioaerosols for many advantages, such as avoiding dehydration of biological agents. However, many previous studies have reported that the liquid impingers are surprisingly inefficient for the collection of ultrafine bioaerosols, with collection efficiencies <30%. In the present work, we have successfully improved the collection efficiency of the liquid impinger (AGI30) to as high as 99% for particles in the size range of 20–400nm with the aid of packed glass beads. We also systematically investigated the effects of influential factors on the collection efficiency. These factors include the volume of the sampling liquid (0, 20 and 30mL), depth (0, 7 and 10cm) of packed glass beads and sampling flow rate (4, 6 and 8 liter per min, lpm). According to our experimental results, increasing the depth of packed glass beads and the volume of sampling liquid can enhance the collection efficiency. Also, decreasing the sampling flow rate can increase the collection efficiency and reduce the loss of sampling liquid. For the sampling of viable MS2 phages, the collection efficiency of AGI30 sampler with packed glass beads is much higher than that without packed glass beads. Conclusively, this study validates that the granular bed filtration can enhance the collection efficiency of liquid impingers for submicron and ultrafine particles and viral aerosols.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • Abstract Liquid impingers are utilized to collect bioaerosols for many advantages, such as avoiding dehydration of biological agents. However, many previous studies have reported that the liquid impingers are surprisingly inefficient for the collection of ultrafine bioaerosols, with collection efficiencies <30%. In the present work, we have successfully improved the collection efficiency of the liquid impinger (AGI30) to as high as 99% for particles in the size range of 20–400nm with the aid of packed glass beads. We also systematically investigated the effects of influential factors on the collection efficiency. These factors include the volume of the sampling liquid (0, 20 and 30mL), depth (0, 7 and 10cm) of packed glass beads and sampling flow rate (4, 6 and 8 liter per min, lpm). According to our experimental results, increasing the depth of packed glass beads and the volume of sampling liquid can enhance the collection efficiency. Also, decreasing the sampling flow rate can increase the collection efficiency and reduce the loss of sampling liquid. For the sampling of viable MS2 phages, the collection efficiency of AGI30 sampler with packed glass beads is much higher than that without packed glass beads. Conclusively, this study validates that the granular bed filtration can enhance the collection efficiency of liquid impingers for submicron and ultrafine particles and viral aerosols.
Subject
  • Aerosols
  • Cooking weights and measures
  • Particulates
  • Physical chemistry
  • Lists by length
  • Aerosol measurement
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software