About: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has now spread across the globe. As part of the worldwide response, many molecular diagnostic platforms have been granted emergency use authorization (EUA) by the Food and Drug Administration (FDA) to identify SARS-CoV-2 positive patients. Our objective was to evaluate three sample-to-answer molecular diagnostic platforms (Cepheid Xpert Xpress SARS-CoV-2 [Xpert Xpress], Abbott ID NOW COVID-19 [ID NOW], and GenMark ePlex SARS-CoV-2 Test [ePlex]) to determine analytical sensitivity, clinical performance, and workflow for the detection of SARS-CoV-2 in nasopharyngeal swabs from 108 symptomatic patients. We found that Xpert Xpress had the lowest limit of detection (100% detection at 100 copies/ml), followed by ePlex (100% detection at 1,000 copies/ml), and ID NOW (20,000 copies/ml). Xpert Xpress also had highest positive percent agreement (PPA) compared to our reference standard (98.3%) followed by ePlex (91.4%) and ID NOW (87.7%). All three assays showed 100% negative percent agreement (NPA). In the workflow analysis, ID NOW produced the lowest time to result per specimen (∼17 min) compared to Xpert Xpress (∼46 min) and ePlex (∼1.5 h), but what ID NOW gained in rapid results, it lost in analytical and clinical performance. ePlex had the longest time to results and showed a slight improvement in PPA over ID NOW. Information about the clinical and analytical performance of these assays, as well as workflow, will be critical in making informed and timely decisions on testing platforms.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has now spread across the globe. As part of the worldwide response, many molecular diagnostic platforms have been granted emergency use authorization (EUA) by the Food and Drug Administration (FDA) to identify SARS-CoV-2 positive patients. Our objective was to evaluate three sample-to-answer molecular diagnostic platforms (Cepheid Xpert Xpress SARS-CoV-2 [Xpert Xpress], Abbott ID NOW COVID-19 [ID NOW], and GenMark ePlex SARS-CoV-2 Test [ePlex]) to determine analytical sensitivity, clinical performance, and workflow for the detection of SARS-CoV-2 in nasopharyngeal swabs from 108 symptomatic patients. We found that Xpert Xpress had the lowest limit of detection (100% detection at 100 copies/ml), followed by ePlex (100% detection at 1,000 copies/ml), and ID NOW (20,000 copies/ml). Xpert Xpress also had highest positive percent agreement (PPA) compared to our reference standard (98.3%) followed by ePlex (91.4%) and ID NOW (87.7%). All three assays showed 100% negative percent agreement (NPA). In the workflow analysis, ID NOW produced the lowest time to result per specimen (∼17 min) compared to Xpert Xpress (∼46 min) and ePlex (∼1.5 h), but what ID NOW gained in rapid results, it lost in analytical and clinical performance. ePlex had the longest time to results and showed a slight improvement in PPA over ID NOW. Information about the clinical and analytical performance of these assays, as well as workflow, will be critical in making informed and timely decisions on testing platforms.
subject
  • Zoonoses
  • COVID-19
  • Cooking weights and measures
  • Companies listed on NASDAQ
  • Medical genetics
  • »more»
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software