About: Abstract The purpose of this subacute 22-day study was to evaluate methods for canine circulating immunoglobulins (IgM, IgG, and IgE) and select B- and T-lymphocyte populations (CD4-helpers, CD8-suppressors, pan-T and pan-B) for immunotoxicity testing using an organ system (concordance) approach. The challenge substance for immunoglobulin testing was repeated immunization with six-way distemper vaccination (DHLAPP), while the challenge substance for leukocyte subpopulations was treatment with cyclophosphamide. Immunoglobulin measurements were made by capture enzyme-linked immunosorbent assay (ELISA), and leukocyte immunophenotyping by fluorescein isothiocyanate/phycoerythrin conjugation (flow cytometry). A battery of parameters that would be used in a typical regulatory study were taken to aid interpretation of the data generated by these methods. Body weights, food consumption, clinical observations, complete clinical chemistry and urinalysis measurements were taken. Gross pathology and micropathology of sternal bone marrow, spleen, mesenteric and retropharyngeal lymph nodes, thymus, liver and kidney were completed. The ELISA method demonstrated acceptable intra-assay reproducibility for IgM, IgG and IgE, with values in good agreement as reported for radial immunodiffusion. The immunologic challenge demonstrated a biological trend of an increase in IgM that preceded an increase in IgG with no discernible trend in IgE response, and no abnormalities in lymphocyte subpopulations. Principle flow cytometry findings related to cyclophosphamide were that the relative percent of B cells decreased dramatically and progressively after compound administration; being statistically decreased in males on day 22 compared with day −5. The relative percent CD4 and CD8 contribution increased, but the CD4/CD8 ratio remained relatively unchanged as total white blood cells decreased progressively. The increase in relative percent CD4 (males only) was statistically significant according to a two-sample t-test on days 17, 20 and 22 when compared with the pre-treatment day −5. There was a relative percent increase in CD5-panT, but absolute numbers were dramatically decreased. We conclude that an organ system approach to assessment of the immune system which incorporates humoral antibody, enumeration of lymphocyte populations and pathologic evaluation of the lymphoreticular organs assists in the interpretation of an adverse toxicological response. The ELISA method for measurement of Igs detected the expected levels of IgG, IgM and IgE due to repeated vaccinations and to cyclophosphamide treatment. The flow cytometry method was acceptable for measuring select canine lymphocyte populations and detecting the expected decrease in B cells due to cyclophosphamide treatment. Both methods may be added to a testing battery for assessing immunotoxicity in canine regulatory studies.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • Abstract The purpose of this subacute 22-day study was to evaluate methods for canine circulating immunoglobulins (IgM, IgG, and IgE) and select B- and T-lymphocyte populations (CD4-helpers, CD8-suppressors, pan-T and pan-B) for immunotoxicity testing using an organ system (concordance) approach. The challenge substance for immunoglobulin testing was repeated immunization with six-way distemper vaccination (DHLAPP), while the challenge substance for leukocyte subpopulations was treatment with cyclophosphamide. Immunoglobulin measurements were made by capture enzyme-linked immunosorbent assay (ELISA), and leukocyte immunophenotyping by fluorescein isothiocyanate/phycoerythrin conjugation (flow cytometry). A battery of parameters that would be used in a typical regulatory study were taken to aid interpretation of the data generated by these methods. Body weights, food consumption, clinical observations, complete clinical chemistry and urinalysis measurements were taken. Gross pathology and micropathology of sternal bone marrow, spleen, mesenteric and retropharyngeal lymph nodes, thymus, liver and kidney were completed. The ELISA method demonstrated acceptable intra-assay reproducibility for IgM, IgG and IgE, with values in good agreement as reported for radial immunodiffusion. The immunologic challenge demonstrated a biological trend of an increase in IgM that preceded an increase in IgG with no discernible trend in IgE response, and no abnormalities in lymphocyte subpopulations. Principle flow cytometry findings related to cyclophosphamide were that the relative percent of B cells decreased dramatically and progressively after compound administration; being statistically decreased in males on day 22 compared with day −5. The relative percent CD4 and CD8 contribution increased, but the CD4/CD8 ratio remained relatively unchanged as total white blood cells decreased progressively. The increase in relative percent CD4 (males only) was statistically significant according to a two-sample t-test on days 17, 20 and 22 when compared with the pre-treatment day −5. There was a relative percent increase in CD5-panT, but absolute numbers were dramatically decreased. We conclude that an organ system approach to assessment of the immune system which incorporates humoral antibody, enumeration of lymphocyte populations and pathologic evaluation of the lymphoreticular organs assists in the interpretation of an adverse toxicological response. The ELISA method for measurement of Igs detected the expected levels of IgG, IgM and IgE due to repeated vaccinations and to cyclophosphamide treatment. The flow cytometry method was acceptable for measuring select canine lymphocyte populations and detecting the expected decrease in B cells due to cyclophosphamide treatment. Both methods may be added to a testing battery for assessing immunotoxicity in canine regulatory studies.
Subject
  • Kidney
  • Antibodies
  • Glycoproteins
  • Isothiocyanates
  • Publications established in 1977
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software