About: Power quality analysis involves the measurement of quantities that characterize a power supply waveform such as its frequency. The measurement of those quantities are regulated by internationally accepted standards from IEEE or IEC. Monitoring the delivered power quality is even more important due to recent advances in power electronics and also due to the increasing penetration of renewable energies in the electrical power grid. The primary suggested method by IEC to measure the power grid frequency is to count the number of zero crossings in the voltage waveform that occur during 0.2 s. The standard zero crossing method is usually applied to a filtered signal that has a non deterministic and frequency dependent delay. For monitoring the power grid a range between 42.5 and 57.5 Hz should be considered which means that the filter must be designed in order to attenuate the delay compensation error. Fuzzy Boolean Nets can be considered a neural fuzzy model where the fuzziness is an inherent emerging property that can ignore some outliers acting as a filter. This property can be useful to apply zero crossing without false crossing detection and estimate the real timestamp without the non deterministic delay concern. This paper presents a comparison between the standard frequency estimation, a Goertzel interpolation method, and the standard method applied after a FBN network instead of a filtered signal.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • Power quality analysis involves the measurement of quantities that characterize a power supply waveform such as its frequency. The measurement of those quantities are regulated by internationally accepted standards from IEEE or IEC. Monitoring the delivered power quality is even more important due to recent advances in power electronics and also due to the increasing penetration of renewable energies in the electrical power grid. The primary suggested method by IEC to measure the power grid frequency is to count the number of zero crossings in the voltage waveform that occur during 0.2 s. The standard zero crossing method is usually applied to a filtered signal that has a non deterministic and frequency dependent delay. For monitoring the power grid a range between 42.5 and 57.5 Hz should be considered which means that the filter must be designed in order to attenuate the delay compensation error. Fuzzy Boolean Nets can be considered a neural fuzzy model where the fuzziness is an inherent emerging property that can ignore some outliers acting as a filter. This property can be useful to apply zero crossing without false crossing detection and estimate the real timestamp without the non deterministic delay concern. This paper presents a comparison between the standard frequency estimation, a Goertzel interpolation method, and the standard method applied after a FBN network instead of a filtered signal.
Subject
  • Electrical systems
  • International Electrotechnical Commission
  • Frequency-domain analysis
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software