About: OBJECTIVE: During the COVID-19 era, a reliable method for tracing aerosols and droplets generated during otolaryngology procedures is needed to accurately assess contamination risk and to develop mitigation measures. Prior studies have not investigated the reliability of different fluorescent tracers for the purpose of studying aerosols and small droplets. Objectives include (1) comparing vitamin B2, fluorescein, and a commercial fluorescent green dye in terms of particle dispersion pattern, suspension into aerosols and small droplets, and fluorescence in aerosolized form and (2) determining the utility of vitamin B2 as a fluorescent tracer coating the aerodigestive tract mucosa in otolaryngology contamination models. METHODS: Vitamin B2, fluorescein, and a commercial fluorescent dye were aerosolized using a nebulizer and passed through the nasal cavity from the trachea in a retrograde-intubated cadaveric head. In another scenario, vitamin B2 was irrigated to coat the nasal cavity and nasopharyngeal mucosa of a cadaveric head for assessment of aerosol and droplet generation from endonasal drilling. A cascade impactor was used to collect aerosols and small droplets ≤14.1 µm based on average aerodynamic diameter, and the collection chambers were visualized under UV light. RESULTS: When vitamin B2 was nebulized, aerosols ≤5.4 µm were generated and the collected particles were fluorescent. When fluorescein and the commercial water tracer dye were nebulized, aerosols ≤8.61 µm and ≤2.08 µm respectively were generated, but the collected aerosols did not appear visibly fluorescent. Endonasal drilling in the nasopharynx coated with vitamin B2 irrigation yielded aerosols ≤3.30 µm that were fluorescent under UV light. CONCLUSION: Vitamin B2’s reliability as a fluorescent tracer when suspended in aerosols and small droplets ≤14.1 µm and known mucosal safety profile make it an ideal compound compared to fluorescein and commercial water-based fluorescent dyes for use as a safe fluorescent tracer in healthcare contamination models especially with human subjects.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • OBJECTIVE: During the COVID-19 era, a reliable method for tracing aerosols and droplets generated during otolaryngology procedures is needed to accurately assess contamination risk and to develop mitigation measures. Prior studies have not investigated the reliability of different fluorescent tracers for the purpose of studying aerosols and small droplets. Objectives include (1) comparing vitamin B2, fluorescein, and a commercial fluorescent green dye in terms of particle dispersion pattern, suspension into aerosols and small droplets, and fluorescence in aerosolized form and (2) determining the utility of vitamin B2 as a fluorescent tracer coating the aerodigestive tract mucosa in otolaryngology contamination models. METHODS: Vitamin B2, fluorescein, and a commercial fluorescent dye were aerosolized using a nebulizer and passed through the nasal cavity from the trachea in a retrograde-intubated cadaveric head. In another scenario, vitamin B2 was irrigated to coat the nasal cavity and nasopharyngeal mucosa of a cadaveric head for assessment of aerosol and droplet generation from endonasal drilling. A cascade impactor was used to collect aerosols and small droplets ≤14.1 µm based on average aerodynamic diameter, and the collection chambers were visualized under UV light. RESULTS: When vitamin B2 was nebulized, aerosols ≤5.4 µm were generated and the collected particles were fluorescent. When fluorescein and the commercial water tracer dye were nebulized, aerosols ≤8.61 µm and ≤2.08 µm respectively were generated, but the collected aerosols did not appear visibly fluorescent. Endonasal drilling in the nasopharynx coated with vitamin B2 irrigation yielded aerosols ≤3.30 µm that were fluorescent under UV light. CONCLUSION: Vitamin B2’s reliability as a fluorescent tracer when suspended in aerosols and small droplets ≤14.1 µm and known mucosal safety profile make it an ideal compound compared to fluorescein and commercial water-based fluorescent dyes for use as a safe fluorescent tracer in healthcare contamination models especially with human subjects.
Subject
  • Membrane biology
  • Physical chemistry
  • Surgical specialties
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2024 OpenLink Software