About: Abstract Rapid thermal cycling (RTC) in an on-chip device can perform DNA amplification in vitro through precise thermal control at each step of the polymerase chain reaction (PCR). This study reports a straightforward fabrication technique for patterning an on-chip graphene-based device with hole arrays, in which the mechanism of surface structures can achieve stable and uniform thermal control for the amplification of DNA fragments. A thin-film based PCR device was fabricated using picosecond laser (PS-laser) ablation of the multilayer graphene (MLG). Under the optimal fluence of 4.72 J/cm2 with a pulse overlap of 66%, the MLG can be patterned with arrays of 250 μm2 hole surface structures. A 354-bp DNA fragment of VP1, an effective marker for diagnosing the BK virus, was amplified on an on-chip device in less than 60 min. A thin-film electrode with the aforementioned MLG as the heater was demonstrated to significantly enhance temperature stability for each stage of the thermal cycle. The temperature control of the heater was performed by means of a developed programmable PCR apparatus. Our results demonstrated that the proposed integration of a graphene-based device and a laser-pulse ablation process to form a thin-film PCR device has cost benefits in a small-volume reagent and holds great promise for practical medical use of DNA amplification.   Goto Sponge  NotDistinct  Permalink

An Entity of Type : fabio:Abstract, within Data Space : covidontheweb.inria.fr associated with source document(s)

AttributesValues
type
value
  • Abstract Rapid thermal cycling (RTC) in an on-chip device can perform DNA amplification in vitro through precise thermal control at each step of the polymerase chain reaction (PCR). This study reports a straightforward fabrication technique for patterning an on-chip graphene-based device with hole arrays, in which the mechanism of surface structures can achieve stable and uniform thermal control for the amplification of DNA fragments. A thin-film based PCR device was fabricated using picosecond laser (PS-laser) ablation of the multilayer graphene (MLG). Under the optimal fluence of 4.72 J/cm2 with a pulse overlap of 66%, the MLG can be patterned with arrays of 250 μm2 hole surface structures. A 354-bp DNA fragment of VP1, an effective marker for diagnosing the BK virus, was amplified on an on-chip device in less than 60 min. A thin-film electrode with the aforementioned MLG as the heater was demonstrated to significantly enhance temperature stability for each stage of the thermal cycle. The temperature control of the heater was performed by means of a developed programmable PCR apparatus. Our results demonstrated that the proposed integration of a graphene-based device and a laser-pulse ablation process to form a thin-film PCR device has cost benefits in a small-volume reagent and holds great promise for practical medical use of DNA amplification.
subject
  • American inventions
  • Digital electronics
  • Orders of magnitude (time)
  • Semiconductor devices
part of
is abstract of
is hasSource of
Faceted Search & Find service v1.13.91 as of Mar 24 2020


Alternative Linked Data Documents: Sponger | ODE     Content Formats:       RDF       ODATA       Microdata      About   
This material is Open Knowledge   W3C Semantic Web Technology [RDF Data]
OpenLink Virtuoso version 07.20.3229 as of Jul 10 2020, on Linux (x86_64-pc-linux-gnu), Single-Server Edition (94 GB total memory)
Data on this page belongs to its respective rights holders.
Virtuoso Faceted Browser Copyright © 2009-2025 OpenLink Software